SUPPORT · LUVIAN

LUVIAN Support

Setup, operation, and maintenance for the big mobile LUVIAN line — high-output units that roll through large facilities. Quick reference below; always follow your unit's owner's manual.

GETTING STARTED

Setup & Deployment

  1. Roll LUVIAN into position — it's built to move through a facility and treat large volumes from a central point in each space.
  2. Mix HOCl solution to 294 PPM (see the Mixing & Maintenance guide) and fill the tank. LUVIAN's larger capacity is built for big rooms and full routes.
  3. Set the run time and start. LUVIAN runs a timed cycle and shuts off automatically. (An optional programmable timer adds self-starting, scheduled cycles.)
  4. Let the unit treat the volume of the room, then move to the next space.
Clean the space first — dry misting layers on top of cleaning, it does not replace it.
OPERATION

Big, Mobile, Timed

LUVIAN is the high-output family: LUVIAN 6 and LUVIAN 10 for large rooms and suites, with a higher-capacity LUVIAN 18 for the largest facilities. All roll through the facility, put out high fog volume, carry a large solution capacity, and run timed cycles with auto shut-off. An optional programmable timer adds self-starting, scheduled cycles.

Detailed installation, tank capacity, and coverage figures are in each model's owner's manual.

MAINTENANCE

Keep LUVIAN Running Like New

Descale every 6 months

Mix one descaler packet with one gallon of water, run it through the unit, let it sit 30–45 minutes, then flush with clean water. Descale more often in hard-water areas. Refer to the product label for the EPA-approved shelf life of mixed solution.

FOGGING TIMES

LUVIAN Fogging Times

LUVIAN 6

Room typeEstimated run time
Office / hotel / hospital room2 min
Classroom7 min
Gym / locker room20 min
Auditorium20 min

Baselines measured in optimal conditions. Airflow and pressure are the determining factor in every application — validate against your space and build SOPs from there. Full coverage figures are in the owner's manual.

LUVIAN 10

Room typeEstimated run time
Office / hotel / hospital room1 min
Classroom5 min
Gym / locker room10 min
Auditorium10 min

Baselines measured in optimal conditions. Airflow and pressure are the determining factor in every application — validate against your space and build SOPs from there. Full coverage figures are in the owner's manual.

LUVIAN 18 delivers the highest output in the family for the largest spaces — run times per its owner's manual.

TROUBLESHOOTING

LUVIAN FAQ

Confirm tank level and correct mixing, then descale — mineral buildup is the most common cause of reduced output. For specific indicator lights or error codes, see the owner's manual or call 855-687-4342.

LUVIAN 6 suits large single rooms; LUVIAN 10 handles bigger volumes and suites; LUVIAN 18 is for the largest facilities. Tell us square footage and ceiling height and we'll spec the unit.

No. Coin replacement is specific to AYRUS. LUVIAN uses different atomization; its main routine maintenance is descaling every 6 months.

HOCl at GEIA working concentration is near-neutral and residue-free. Follow your facility SOP and the tablet label for occupied-space use in your application.

VIDEO WALKTHROUGHS

Watch: LUVIAN How-To

LUVIAN Series โ€” Startup Process

Starting up the LUVIAN series for a treatment cycle.

Setting the Countdown Timer

The countdown timer is standard on LUVIAN โ€” how to change the run-time duration.

Need the Full Manual or a Hand?