DRY MISTING SYSTEMS

ROGE.

Set it in place and start it. ROGE is GEIA's set-in-place system — intermittent HOCl fog cycles with variable output and automatic shut-off, running hands-off in the room until the cycle ends. Available as Roge Mini, Roge One, and Roge 3.

ROGE dry misting units — Mini, One, and 3
Set in place, started when you need it, working on its own. ROGE lives in the room that needs treatment — the exam room, the office, the kennel, the small classroom — and runs intermittent fog cycles until they finish. The room is treated whether or not anyone is standing in it.
WHAT ROGE DOES

Set-in-place. Intermittent. Built to run hands-off.

ROGE delivers the same HOCl mist technology as the rest of the GEIA platform, in a unit that stays put in the room it treats. Start it and it runs intermittent fog cycles at the fog setting you choose, shutting off automatically when the cycle ends.

⏱️

Start It, Walk Away

Feature: Intermittent fog cycles with variable output and automatic shut-off — Mini for small rooms, One and 3 for progressively larger fixed spaces.

Result: Start the unit and the room is treated hands-off — no one has to stand by to stop it, since it shuts off on its own when the cycle ends.

🎯

One Room, One Unit

Feature: Designed to live in a single fixed room — exam room, office, kennel, dental op, small classroom — where steady, intermittent treatment is the right answer.

Result: Consistent, hands-off treatment for that room without dedicating a portable unit or a person to it.

🤝

Same Chemistry, Same Standard

Feature: Loads with the same HOCl chemistry as AYRUS and LUVIAN — tablets, RTU, or generated. 294 ppm target, 300 ppm equipment max.

Result: A set-in-place ROGE delivers the same chemistry standard as a portable AYRUS unit or a big mobile LUVIAN.

HOW ROGE FITS YOUR PROTOCOL

ROGE works alongside your cleaning routine. Never as a replacement for it.

1

The room gets cleaned

Standard cleaning happens first — wipe down, remove soil, change linens or pads. ROGE does not replace this step.

2

High-touch surfaces wiped

Door handles, switches, counters, equipment grips. Same cadence as today.

3

ROGE runs its fog cycle

The unit, set in place in the room, runs its intermittent fog cycle and shuts off automatically when the cycle ends.

ROGE does not run continuously. It runs intermittent fog cycles — started when you need them, then running on their own with auto shut-off.

SPECIFICATIONS

Roge Mini, One & 3 — Side by Side

Fog output and unit weight are confirmed below. Tank capacity and run time per fill are specified in each model's owner's manual and vary with fill level and cycle settings.

ModelRoge Mini
Form factorSet-in-place, small footprint — lives in the room it treats
OperationIntermittent fog cycles, variable fog output, auto shut-off
Fog output rate0.5 L/hr
Tank capacity1 gallon
Run time per fill~8 hours on a full tank
CoverageSmall fixed rooms — office / exam room ≈ 15 min, classroom ≈ 45 min per fogging baselines
Operating chemistryHypochlorous acid (HOCl), up to 300 ppm — equipment maximum
Target working concentration294 ppm (per EPA-registered tablet labels)
HOCl sourceCompatible with EPA-registered tablets, ready-to-use (RTU) HOCl, or on-site HOCl generators
ControlsOn-unit controls (variable fog output, intermittent cycles, auto shut-off)
Net weight6 lb (unit dimensions per owner's manual)
Maintenance — descalingEvery 6 months (see Support)
ModelRoge One
Form factorSet-in-place, mid-size — the everyday workhorse for a fixed room
OperationIntermittent fog cycles, variable fog output, auto shut-off
Fog output rate1.5 L/hr
Tank capacity4 gallons
Run time per fill~10 hours on a full tank
CoverageMid-size fixed rooms — office ≈ 10 min, classroom ≈ 30 min, gym / locker room ≈ 60 min per fogging baselines
Operating chemistryHypochlorous acid (HOCl), up to 300 ppm — equipment maximum
Target working concentration294 ppm (per EPA-registered tablet labels)
HOCl sourceCompatible with EPA-registered tablets, ready-to-use (RTU) HOCl, or on-site HOCl generators
ControlsOn-unit controls (variable fog output, intermittent cycles, auto shut-off)
Net weight14 lb (unit dimensions per owner's manual)
Maintenance — descalingEvery 6 months (see Support)
ModelRoge 3
Form factorSet-in-place, higher capacity — for larger fixed rooms
OperationIntermittent fog cycles, variable fog output, auto shut-off
Fog output rate3.0 L/hr
Tank capacity5 gallons
Run time per fill~6 hours on a full tank
CoverageLarger fixed rooms — office ≈ 6 min, classroom ≈ 20 min, gym ≈ 45 min, auditorium ≈ 60 min per fogging baselines
Operating chemistryHypochlorous acid (HOCl), up to 300 ppm — equipment maximum
Target working concentration294 ppm (per EPA-registered tablet labels)
HOCl sourceCompatible with EPA-registered tablets, ready-to-use (RTU) HOCl, or on-site HOCl generators
ControlsOn-unit controls (variable fog output, intermittent cycles, auto shut-off)
Net weight24 lb (unit dimensions per owner's manual)
Maintenance — descalingEvery 6 months (see Support)
SpecRoge MiniRoge OneRoge 3
Fog output rate0.5 L/hr1.5 L/hr3.0 L/hr
Tank capacity1 gal4 gal5 gal
Run time per fill (full tank)~8 hr~10 hr~6 hr
Net weight6 lb14 lb24 lb
OperationSet-in-place, intermittentSet-in-place, intermittentSet-in-place, intermittent
Room sizeSmallest fixed roomsMid-size fixed roomsLarger fixed rooms
Equipment max PPM≤ 300 ppm≤ 300 ppm≤ 300 ppm
HOCl sourceTablets / RTU / generatorTablets / RTU / generatorTablets / RTU / generator
Best forSmall offices, single exam rooms, tight kennelsDental/vet offices, single kennels, small classroomsLarger offices, classrooms, multi-run kennels, big single-room work
ROGE is an application method. It does not carry independent disinfectant claims. All kill claims and use directions are governed by the EPA-registered label of the HOCl product loaded into the system. Always follow the EPA label for use sites, pre-cleaning, contact times, and PPE.
WHO RUNS ROGE

A set-in-place unit that runs itself.

ROGE is the GEIA system that lives in the room and runs on a set routine. The three most common patterns we see:

🏢

Single-room businesses

Small dental and vet offices, single-suite kennels, boutique studios. One ROGE set in the room, started to run intermittent cycles around business hours.

🗓️

Fixed rooms on a set routine

Exam rooms, treatment rooms, small classrooms, back offices. ROGE stays put and runs intermittent cycles on its own automatic clock.

🐾

Kennels & care rooms

Kennel runs, grooming rooms, recovery rooms. Set-in-place treatment that runs unattended between occupants — no operator standing by.

WHAT IT WORKS WITH

HOCl, from any source you prefer.

ROGE is HOCl-source agnostic. Load it with EPA-registered tablets, ready-to-use HOCl, or on-site HOCl generation — whatever fits your facility's logistics. The target working concentration is 294 ppm; the equipment maximum is 300 ppm. For single-room set-in-place use, tablets are the most common choice — pre-measured, shelf-stable, easy to keep on hand.

HOCl pH ≈ 6.5 (near-neutral). The same molecule the human immune system produces — up to 80× more powerful than bleach, safe around people, animals, and food.

WHAT FACILITIES SEE

Outcomes the operator actually feels.

🕒

Treatment on a set routine, hands-off

Program the cycles once and the room is treated on a predictable clock — between occupants and after hours — without anyone starting or stopping the unit.

📦

Right-sized footprint

One unit set in the room, one bucket of tablets. A real biosecurity standard for a single space, without a portable unit or a person tied to it.

💨

Same chemistry as the rest of the line

A set-in-place ROGE loads the same HOCl chemistry as a portable AYRUS or a big mobile LUVIAN. Consistent standard across the platform.

👃

Odor removal at the molecule

HOCl oxidizes odor compounds. Exam rooms, kennels, offices — smells don't return when the fog cycle ends.

MAINTENANCE

Documented, scheduled, simple.

ROGE follows the same maintenance discipline as the rest of the GEIA platform — periodic descaling on a documented schedule. Full steps, intervals, and video walkthroughs live in the support hub. The PPM ceiling and mixed-solution shelf life are the same on every GEIA unit.

Go to ROGE Support

Service Schedule

DescalingEvery 6 months
Operating PPM ceiling≤ 300 ppm (never exceed)
Target working PPM294 ppm
Mixed-solution shelf life24 hours (tablet-mixed HOCl)
Owner's manualROGE Owner's Manual — PDF in support
QUESTIONS

FAQ — ROGE

AYRUS is the portable, carry-anywhere flagship you move room to room. LUVIAN is the big mobile unit that rolls through large facilities. ROGE is the set-in-place unit that lives in a fixed room and runs intermittent fog cycles with auto shut-off. Same HOCl chemistry across all three; the question being answered is different.

Roge Mini is the smallest — small offices, single exam rooms, tight kennels. Roge One is the mid-size workhorse — dental and vet offices, single kennels, small classrooms. Roge 3 is the largest — larger offices, classrooms, multi-run kennels, and the biggest single rooms a set-in-place unit covers. Tell us your room size and we'll spec the right unit.

The typical operational pattern is to program cycles to run between occupants — the exam room between patients, the kennel between animals, the office after hours. HOCl itself is the same molecule the human immune system produces and is safe around people, animals, and food; follow the EPA-registered label of the HOCl product you load for any specific use directions.

No. ROGE runs intermittent fog cycles — started when you need them, then running on their own with auto shut-off. It treats the room in intervals rather than running non-stop.

Any HOCl source up to 300 ppm. For single-room set-in-place use, EPA-registered tablets (3.3g or 6.5g Tablets) are the most common choice — pre-measured, shelf-stable, easy to keep on hand. Ready-to-use HOCl and on-site HOCl generators also work. The target working concentration is 294 ppm; the equipment maximum is 300 ppm.

Yes. ROGE works on top of standard cleaning, never in place of it. Wipe down, remove soil, change linens or pads. Then ROGE runs its fog cycle. This sequence is the one we recommend on every page of the site.

Røg — Danish for smoke. ROGE puts the mist exactly where you point it.

Talk to us about your room.

Tell us what you're treating — the room, its size, how often you want cycles to run. We'll spec the right set-in-place ROGE model and tablet supply for your space.

Get a Quote

855-687-4342 · sales@geiasolutions.com