LUVIAN.
Whole rooms, treated end to end — between cycles, between patients, between guests. LUVIAN is GEIA's set-up-and-treat system: ultrasonic sub-5-micron HOCl mist that fills the volume of the room, then dissipates. Available as LUVIAN 6, LUVIAN 10, and LUVIAN 18 — the highest-output unit in the GEIA family.
Sub-5-micron mist. Whole-volume coverage. One cycle per turnover.
LUVIAN uses ultrasonic technology to produce a hypochlorous (HOCl) mist with droplets smaller than five microns — for scale, a human hair is roughly 70 microns and an E. coli cell is 1–3 microns. At that size, the mist behaves more like a gas than a spray: it fills the volume of a room, contacts surfaces wipes can't reach, and dissipates without residue.
Treats the Whole Room
Feature: Sub-5-micron ultrasonic mist behaves like a gas, filling the volume of the space — under furniture, behind equipment, into corners that don't get wiped.
Result: The room is treated, not just the surfaces someone remembered to spray.
Built for Turnover
Feature: Place LUVIAN in the room, start the cycle, walk out. The unit runs the cycle on its own and finishes before the next use.
Result: Surgical suite, hotel room, flower room, or classroom is ready for the next occupant on a predictable clock.
Dry Mist, No Residue
Feature: Droplets are small enough that they don't pool, drip, or leave surfaces wet. The mist dissipates as it works.
Result: No towel-down step, no streaks on stainless or glass, no waiting on surfaces to dry.
Three units. Sized to the room.
LUVIAN 6 is sized for smaller timed-treatment rooms — exam rooms, single hotel rooms, small classrooms, vet rooms. LUVIAN 10 handles larger volumes — surgical suites, suites of guest rooms, cannabis flower rooms, gymnasiums. LUVIAN 18 is the highest-output unit in the GEIA family, built for the largest spaces and fastest turnarounds.

Best for: single hotel rooms on turnover, exam rooms, smaller classrooms, vet rooms, mortuary prep, single-suite turnover.
See spec sheet →
Best for: surgical suites, cannabis flower rooms, larger classrooms and gymnasiums, hospitality suites, larger commercial spaces.
See spec sheet →
Best for: large warehouses and processing floors, big gymnasiums and auditoriums, large-scale cultivation, whole-facility programs.
See spec sheet →All three units share the same 10-gallon tank, the same chemistry, the same mist particle size, and the same maintenance schedule. The difference is output — 6.5, 10, or 18 L/hr — which sets how fast each treats a space and how long a full tank runs. See specs below.
LUVIAN works alongside your cleaning team. Never as a replacement for it.
Your team cleans
Sweep, mop, change linens, remove soil. Standard turnover cleaning stays in place. LUVIAN does not replace this step.
Your team wipes down high-touch
Doorknobs, rails, switches, controls, shared equipment. Same cadence as today.
LUVIAN runs the cycle
Place the unit in the room, start the cycle, close the door. The room is treated end to end before the next occupant arrives.
LUVIAN does not run continuously. It runs one timed cycle per turnover — between patients, between guests, between flower-room batches, between class days.
LUVIAN 6, 10 & 18 — Side by Side
Fog output and unit weight are confirmed below. Tank capacity and run time per fill are specified in each model's owner's manual and vary with fill level and cycle settings.
| Model | LUVIAN 6 |
|---|---|
| Form factor | Floor unit — place in the room, run the cycle, remove |
| Technology | Ultrasonic mist generation |
| Droplet size | Sub-5-micron dry mist |
| Fog output rate | 6.5 L/hr |
| Tank capacity | 10 gallons |
| Run time per fill | ~6 hours on a full tank |
| Timer | Countdown; optional 7-day programmable |
| Coverage / room-size guidance | Smaller rooms — e.g. office / hotel / hospital room ≈ 2 min, classroom ≈ 7 min per fogging baselines |
| Operating chemistry | Hypochlorous acid (HOCl), up to 300 ppm — equipment maximum |
| Target working concentration | 294 ppm (per EPA-registered tablet labels) |
| HOCl source | Compatible with EPA-registered tablets, ready-to-use (RTU) HOCl, or on-site HOCl generators |
| Net weight | 95 lb (unit dimensions per owner's manual) |
| Maintenance — descaling | Every 6 months (see Support) |
| Model | LUVIAN 10 |
|---|---|
| Form factor | Floor unit — place in the room, run the cycle, remove |
| Technology | Ultrasonic mist generation |
| Droplet size | Sub-5-micron dry mist |
| Fog output rate | 10.0 L/hr |
| Tank capacity | 10 gallons |
| Run time per fill | ~4 hours on a full tank |
| Timer | Countdown; optional 7-day programmable |
| Coverage / room-size guidance | Larger rooms — e.g. office / hotel / hospital room ≈ 1 min, classroom ≈ 5 min, gym ≈ 10 min per fogging baselines |
| Operating chemistry | Hypochlorous acid (HOCl), up to 300 ppm — equipment maximum |
| Target working concentration | 294 ppm (per EPA-registered tablet labels) |
| HOCl source | Compatible with EPA-registered tablets, ready-to-use (RTU) HOCl, or on-site HOCl generators |
| Net weight | 105 lb (unit dimensions per owner's manual) |
| Maintenance — descaling | Every 6 months (see Support) |
| Model | LUVIAN 18 |
|---|---|
| Form factor | Floor unit — place in the room, run the cycle, remove |
| Technology | Ultrasonic mist generation |
| Droplet size | Sub-5-micron dry mist |
| Fog output rate | 18.0 L/hr — highest output in the GEIA family |
| Tank capacity | 10 gallons |
| Run time per fill | ~2 hours on a full tank (highest output empties fastest) |
| Timer | Countdown; optional 7-day programmable |
| Coverage / room-size guidance | Largest spaces — warehouses, processing floors, big gymnasiums and auditoriums, large-scale cultivation |
| Operating chemistry | Hypochlorous acid (HOCl), up to 300 ppm — equipment maximum |
| Target working concentration | 294 ppm (per EPA-registered tablet labels) |
| HOCl source | Compatible with EPA-registered tablets, ready-to-use (RTU) HOCl, or on-site HOCl generators |
| Net weight | 143 lb (unit dimensions per owner's manual) |
| Maintenance — descaling | Every 6 months (see Support) |
| Spec | LUVIAN 6 | LUVIAN 10 | LUVIAN 18 |
|---|---|---|---|
| Fog output rate | 6.5 L/hr | 10.0 L/hr | 18.0 L/hr |
| Tank capacity | 10 gal | 10 gal | 10 gal |
| Run time per fill (full tank) | ~6 hr | ~4 hr | ~2 hr |
| Net weight | 95 lb | 105 lb | 143 lb |
| Timer | Countdown | Countdown | Countdown |
| Room-size fit | Smaller rooms | Larger rooms / suites | Largest spaces / facilities |
| Droplet size | Sub-5 micron | Sub-5 micron | Sub-5 micron |
| Equipment max PPM | ≤ 300 ppm | ≤ 300 ppm | ≤ 300 ppm |
| HOCl source | Tablets / RTU / generator | Tablets / RTU / generator | Tablets / RTU / generator |
| Form factor | Floor unit, portable into room | Floor unit, portable into room | Floor unit, portable into room |
| Best for | Single hotel rooms, exam rooms, classrooms, vet rooms | Surgical suites, flower rooms, gymnasiums, suites | Warehouses, processing floors, large cultivation, whole-facility programs |
Countdown standard. Programmable optional.
LUVIAN comes standard with a countdown timer — set the run time and it shuts off on its own. Upgrade to the 7-day programmable timer for self-starting, scheduled cycles. Full details on the Accessories page.

Countdown — Standard
Set a run length; the unit stops on its own. Included with every LUVIAN.

Programmable — Upgrade
7-day self-starting schedule. Optional upgrade for hands-off, recurring cycles.
Why sub-5 microns is the whole point.
A wipe-and-spray covers what the operator can see and reach. A conventional fogger drops larger droplets that fall out of the air. LUVIAN's ultrasonic mist is small enough to behave like a gas — and the scale comparison makes that intuitive.
Human hair
≈ 70 microns. Visible. Heavy. Falls.
E. coli cell
1–3 microns. Invisible to the eye. Lives on surfaces, in air, in pooled water.
LUVIAN mist
Sub-5 microns. Small enough to suspend in air, contact every surface, and reach into shadowed space — then dissipate.
HOCl, from any source you prefer.
LUVIAN is HOCl-source agnostic. Load it with EPA-registered tablets, ready-to-use HOCl, or on-site HOCl generation — whatever fits your facility's logistics and budget. The target working concentration is 294 ppm; the equipment maximum is 300 ppm.



HOCl pH ≈ 6.5 (near-neutral). The same molecule the human immune system produces — up to 80× more powerful than bleach, safe around people, animals, and food.
Where LUVIAN shines.
LUVIAN is built for rooms that turn over — environments where one occupant ends, the room is reset, and the next occupant arrives. Whole-room treatment, in the window you already have for turnover.






Outcomes operations teams actually feel.
Faster, more consistent turnover
The treatment step runs on its own while the team moves on. Turnover finishes when the cycle finishes — no operator standing in the room.
Whole-volume coverage
Sub-5-micron mist reaches behind furniture, under equipment, into ceiling corners. Coverage that doesn't depend on operator thoroughness.
Air treated, not just surfaces
HOCl mist works on air and surfaces in the same cycle — a layer most disinfection methods miss entirely.
Odor removal at the molecule
HOCl oxidizes odor compounds. No fragrance, no masking — locker, mortuary, and pet odors don't return when the air clears.
Documented, scheduled, simple.
LUVIAN uses ultrasonic mist generation; periodic descaling is the primary scheduled service item. Full maintenance steps, intervals, and video walkthroughs are in the support hub. The PPM ceiling and mixed-solution shelf life follow the same rules as the rest of the GEIA platform.
Go to LUVIAN SupportService Schedule
| Descaling | Every 6 months |
|---|---|
| Operating PPM ceiling | ≤ 300 ppm (never exceed) |
| Target working PPM | 294 ppm |
| Mixed-solution shelf life | 24 hours (tablet-mixed HOCl) |
| Owner's manual | LUVIAN Dry Misting System (Feb 2025) — PDF in support |
FAQ — LUVIAN
AYRUS is the portable, carry-anywhere flagship you move room to room — flexible, powerful, and compact, running cycles in occupied spaces on the air people are already breathing. LUVIAN is the big mobile unit for large facilities — high output and large capacity for rooms that turn over: surgical suite between cases, hotel room between guests, classroom between days. Same HOCl chemistry, same sub-5-micron particle behavior. Different question being answered.
Conventional foggers produce larger, wetter droplets that fall out of the air quickly, leave surfaces visibly wet, and typically require long dwell times. LUVIAN's ultrasonic mist is sub-5 micron — it behaves like a gas, fills the volume of the room, contacts surfaces wipes can't reach, and dissipates without residue.
LUVIAN is designed for turnover — the typical use is between occupants, with the room closed during the cycle. HOCl itself is the same molecule the human immune system produces and is safe around people, animals, and food; the room-closed cycle is the operational pattern, not a safety requirement. Follow the EPA-registered label of the HOCl product you load for any specific use directions.
No. LUVIAN runs one timed cycle per turnover — set it up in the room, start the cycle, the unit shuts down when the cycle is complete. An optional programmable timer can add self-starting, scheduled cycles. The room is then treated and ready for the next occupant.
LUVIAN 6 is sized for smaller rooms — single hotel rooms, exam rooms, smaller classrooms. LUVIAN 10 handles larger volumes — surgical suites, cannabis flower rooms, larger classrooms and gymnasiums. Tell us your square footage and ceiling height and we'll spec the right unit. Detailed coverage figures are in each model's owner's manual.
Any HOCl source up to 300 ppm. Most facilities use EPA-registered tablets (3.3g or 6.5g Tablets) because they're pre-measured and shelf-stable. Ready-to-use HOCl and on-site HOCl generators also work. The target working concentration is 294 ppm; the equipment maximum is 300 ppm.
Yes. LUVIAN works on top of standard cleaning, never in place of it. Clean and reset the room. Wipe down high-touch surfaces. Then LUVIAN runs the cycle. This sequence is the one we recommend on every page of the site.
A nod to lluvia — Spanish for rain. LUVIAN is the room-and-rain system: timed, gentle, whole-volume.
Talk to us about your turnover.
Tell us the room — square footage, ceiling height, what happens in it, how often it turns over. We'll spec the right LUVIAN model and cycle setup for your space.
Get a Quote